CLI Command Navigation
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m .

CLI Command Configuration Options

You can configure the software in one of two ways:

Displaying the Switch Configuration

You can view the ASCII form of the configuration file when required. To view the current configuration
tree from the EXEC prompt, issue the show running-config command. If the running configuration is
different from the startup configuration, issue the show startup-config command to view the ASCII
version of the current startup configuration that was used to boot the switch if a copy run start command
was not issued after the reboot. Use the show startup command to view the contents of the current
startup configuration.
You can also gather specific information on the entire switch configuration by issuing the relevant show
commands. Configurations are displayed based on a specified feature, interface, module, or VSAN.
Available show commands for each feature are briefly described in this section and listed at the end of
each chapter.
Examples
Example 2-2
switch# show interface fc1/1
fc1/1 is up
Cisco MDS 9000 Family Configuration Guide
2-10
Delete a created facility.
If you want to delete a zone that you created:
switch(config)# zone name test vsan 1
switch(config-zone)# exit
switch(config)# no zone name test vsan 1
switch(config)#
You cannot delete a zone facility called test while residing in it. You must first exit the zone submode
and return to configuration mode.
You can create the configuration for the switch interactively by issuing commands at the CLI
prompt.
You can create an ASCII file containing a switch configuration and then load this file on the required
system. You can then use the CLI to edit and activate the file (see the
Files" section on page
7-1).
2-2
to
2-8
display a few show command examples.
Displays Details on the Specified Interface
Hardware is Fibre Channel, 20:01:ac:16:5e:4a:00:00
vsan is 1
Port mode is E
Speed is 1 Gbps
Beacon is turned off
FCID is 0x0b0100
0 frames input, 0 bytes, 0 discards
0 runts, 0 jabber, 0 too long, 0 too short
0 input errors, 0 CRC, 0 invalid transmission words
0 address id, 0 delimiter
0 EOF abort, 0 fragmented, 0 unknown class
0 frames output, 0 bytes, 0 discards
Received 0 OLS, 0 LRR, 0 NOS, 0 loop inits
Transmitted 0 OLS, 0 LRR, 0 NOS, 0 loop inits
Chapter 2
Before You Begin
"Working with Configuration
OL-6973-03, Cisco MDS SAN-OS Release 2.x

Advertisement

Table of Contents
loading