Verifying the Status of a Module

S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m .
Verifying the Status of a Module
Before you begin configuring the switch, you need to ensure that the modules in the chassis are
functioning as designed. To verify the status of a module at any time, issue the show module command
(see the
configured when the
show module command follows:
switch# show module
Mod
---
2
4
5
6
8
9
Mod
---
2
5
6
8
9
Mod
---
2
5
6
8
9
* this terminal session
The Status column in the output should display an
standby (or HA-standby) status for supervisor modules. If the status is either ok or active, you can
continue with your configuration.
A standby supervisor module reflects the HA-standby status if the HA switchover mechanism is enabled
Note
(see the
enabled, the standby supervisor module reflects the standby status.
The states through which a switching module progresses is discussed in the
Module" section on page

Checking the State of a Module

If your chassis has more than one switching module (also known as line card), you can check the
progress by issuing the show module command several times and viewing the
The switching module goes through a testing and an initializing stage before displaying an
Table 10-3
Cisco MDS 9000 Family Configuration Guide
10-4
"Fibre Channel Interfaces" section on page
status is displayed in the show module command output. A sample output of the
ok
Ports
Module-Type
-----
------------------------------- ------------------ ------------
8
IP Storage Services Module
0
Caching Services Module
0
Supervisor/Fabric-1
0
Supervisor/Fabric-1
0
Caching Services Module
32
1/2 Gbps FC Module
Sw
Hw
World-Wide-Name(s) (WWN)
-----------
------
--------------------------------------------------
1.3(0.106a)
0.206
20:41:00:05:30:00:00:00 to 20:48:00:05:30:00:00:00
1.3(0.106a)
0.602
--
1.3(0.106a)) 0.602
--
1.3(0.106a)
0.702
--
1.3(0.106a)
0.3
22:01:00:05:30:00:00:00 to 22:20:00:05:30:00:00:00
MAC-Address(es)
--------------------------------------
00-05-30-00-9d-d2 to 00-05-30-00-9d-de
00-05-30-00-64-be to 00-05-30-00-64-c2
00-d0-97-38-b3-f9 to 00-d0-97-38-b3-fd
00-05-30-01-37-7a to 00-05-30-01-37-fe
00-05-30-00-2d-e2 to 00-05-30-00-2d-e6
"HA Switchover Characteristics" section on page
10-4.
describes the possible states in which a module can exist.
11-2). The interfaces in each module are ready to be
Model
DS-X9308-SMIP
DS-X9530-SF1-K9
DS-X9530-SF1-K9
DS-X9560-SMAP
DS-X9032
<--------------- New running version in module 6
Serial-Num
----------
JAB064605a2
JAB06350B1R
JAB072705ja
JAB06280ae9
status for switching modules and an active or
ok
8-2). If the warm switchover mechanism is
Chapter 10
Managing Modules
Status
ok
ok
active *
ha-standby
ok
ok
"Checking the State of a
column each time.
Status
ok
OL-6973-03, Cisco MDS SAN-OS Release 2.x
status.