MBCS data to be copied to an NSS volume on an OES Linux server,
conversion must take place from MBCS to Unicode* and certain Japanese
characters might not come through intact.
Action: If you have double-byte character data on a NetWare 5.1 server that you want
to copy to OES Linux, follow the instructions in
Double-Byte Character Set Data," on page
Errors When Migrating a Cluster Volume
Problem: When using the Server Consolidation Utility and migrating data from or to a
cluster volume, an error (0xFFFDAE) might occur if your cluster server nodes
are spread throughout different eDirectory contexts. If the server (from the
SCU project) that holds the mounted cluster volumes does not have rights to
the cluster Virtual Server object and the cluster-enabled Volume object, and
does not have a Read/Write replica of the partition these objects reside in, then
a failure fffdae is displayed on the verification screen of the Server
Consolidation Utility.
Action: To resolve this, add the server as a trustee of the context that contains the
Virtual Server and Cluster Volume objects. The default rights assigned when
adding the trustee are sufficient.
Problem: When migrating data to or from a NetWare 5.1 cluster volume, the copy fails
with a critical error: "Error opening connection to SMDR."
Action: For the Server Consolidation Utility to function properly with a NetWare 5.1
cluster-enabled volume, you must use the server name followed by an
underscore followed by the Volume Name object (for example, server1_vol1).
For details, see
Cluster," on page
Unloading NUWAGENT.NLM on an Nterprise Branch Office Appliance
Problem: When running the Server Consolidation Utility in conjunction with an
Nterprise Branch Office appliance, if an error state occurs and you are asked to
unload nuwagent.nlm, the system might not allow you to unload the
module.
Action: Perform a reboot of the Nterprise Branch Office appliance.

Errors When Connecting to a NetWare 4 Server

Problem: When attempting to connect to a NetWare 4 server, any of the following types
of errors are returned:
• An error occurred opening the file. filename was invalid.
• Error opening connection to SMDR.
• The name spaces couldn't be checked.
• 8998 error. NWGetVolumeNumber.
Action: There are several actions to take if errors are returned when trying to connect
to a NetWare 4 server, including the following:
Section 6.9, "Consolidating Data to or from a NetWare 5.1
56.
Chapter 13, "Copying
117.
Troubleshooting Server Consolidations
85