System Configuration - Dell DX6000G Hardware Owner's Manual

Hardware owner's manual
Hide thumbs Also See for DX6000G:
Table of Contents

Advertisement

Table 1-1. LCD Status Messages
Code
Text
I1911
LCD Log Full.
Check SEL to
review all
Errors.
I1912
SEL full.
Review & clear
log.
I1920
iDRAC6 Upgrade
Successful
W1228
RAID
Controller
battery
capacity <
24hr.
W1627
Power required
> PSU wattage.
Check PSU and
config.
W1628
Performance
degraded.
Check PSU and
system
configuration.
NOTE:
For the full name of an abbreviation or acronym used in this table, see the
Glossary at support.dell.com/manuals.
(continued)
Causes
LCD overflow message.
A maximum of ten error
messages can display
sequentially on the LCD.
The eleventh message
instructs the user to check
the SEL for details on the
events.
The SEL is full of events
and is unable to log any
more.
Optional iDRAC6 has
been upgraded
successfully.
Warns predictively that
the RAID battery has
less than 24 hours of
charge left.
The system configuration
requires more power
than what the power
supply can provide.
The system configuration
requires more power
than what the power
supply can provide, but it
can boot if throttled.
Corrective Actions
Check the SEL for details
on the events.
Remove AC power to the
system for 10 seconds or
clear the SEL.
Check the SEL for details
on the events, then clear
the SEL.
Information only.
Allow RAID battery to
charge to greater than
24 hours of
sustained charge.
If problem persists,
replace RAID battery.
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.