Cpu Heatsink - Dell DX6000G Hardware Owner's Manual

Hardware owner's manual
Hide thumbs Also See for DX6000G:
Table of Contents

Advertisement

Table 1-1. LCD Status Messages
Code
Text
E1410
Internal Error
detected.
Check "FRU X".
E1414
CPU # temp
exceeding
range. Check

CPU heatsink.

E1418
CPU # not
detected.
Check CPU is
seated
properly.
E141C
Unsupported
CPU
configuration.
Check CPU or
BIOS revision.
E141F
CPU # protocol
error. Power
cycle AC.
24
About Your System
(continued)
Causes
Specified processor has an
internal error. The error
may or may not have been
caused by the processor.
Specified processor is out
of acceptable temperature
range.
Specified processor is
missing or bad, and the
system is in an
unsupported
configuration.
Processors are in an
unsupported
configuration.
The system BIOS
has reported a processor
protocol error.
Corrective Actions
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 169.
Ensure that the processor
heat sinks are properly
installed. See
"Troubleshooting the
Processors" on page 156
and "Troubleshooting
System Cooling
Problems" on page 147.
Ensure that the specified
microprocessor is
properly installed. See
"Troubleshooting the
Processors" on page 156.
Ensure that your
processors match and
conform to the type
described in the processor
technical specifications
outlined in your system's
Getting Started Guide.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 169.