Dell DX6000G Hardware Owner's Manual page 45

Hardware owner's manual
Hide thumbs Also See for DX6000G:
Table of Contents

Advertisement

Table 1-2. System Messages
Message
Sector not found
Seek error
Seek operation
failed
Shutdown failure General system error.
Sparing mode
disabled. For
sparing mode,
matched sets of
three must be
populated across
slots.
The amount of
system memory has
changed
(continued)
Causes
Faulty hard drive, USB
device, or USB medium.
The memory configuration
does not match the setting in
BIOS. The BIOS setting has
been disabled.
Memory has been added or
removed or a memory
module may be faulty.
Corrective Actions
Replace the USB medium or
device. Ensure that the USB
or SAS backplane cables are
properly connected. See
"Troubleshooting a USB
Device" on page 142 or
"Troubleshooting a Hard
Drive" on page 152 for the
appropriate drive(s) installed
in your system.
See "Getting Help" on
page 169.
Reconfigure the memory
modules for Memory
Sparing mode. See "System
Memory" on page 110.
If memory has been added or
removed, this message is
informative and can be
ignored. If memory has not
been added or removed,
check the SEL to determine
if single-bit or multi-bit
errors were detected and
replace the faulty memory
module.
See "Troubleshooting
System Memory" on
page 148.
About Your System
45

Advertisement

Table of Contents
loading

Table of Contents