Table 1-1. LCD Status Messages
Code
Text
E1620
Power Supply #
(### W) AC
power error.
Check PSU
cables.
E1624
Lost power
supply
redundancy.
Check PSU
cables.
E1626
Power Supply
Mismatch. PSU1
= ### W, PSU2
= ### W.
E1629
Power required
> PSU wattage.
Check PSU and
config.
E1710
I/O channel
check error.
Review & clear
SEL.
26
About Your System
(continued)
Causes
Specified power supply's
AC input is outside of the
allowable range.
The power supply
subsystem is no longer
redundant. If the
remaining power supply
fails, the system will
shut down.
The power supplies in
the system are not the
same wattage.
The system configuration
requires more power than
the power supplies can
provide, even with
throttling.
The system BIOS has
reported an I/O channel
check.
Corrective Actions
Check the AC power
source for the specified
power supply. If the
problem persists,
see "Troubleshooting
Power Supplies" on
page 147.
See "Troubleshooting
Power Supplies" on
page 147.
Ensure that power
supplies with matching
wattage are installed.
See the Technical
Specifications outlined in
your system's Getting
Started Guide.
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.
Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.
If the problem persists,
see "Getting Help" on
page 169.