Table 1-2. LCD Status Messages (Optional)
Code
Text
E1410
System Fatal
Error
detected.
E1414
CPU # temp
exceeding
range. Check

CPU heatsink.

E1418
CPU # not
detected.
Check CPU is
seated
properly.
E141C
Unsupported
CPU
configuration.
Check CPU or
BIOS revision.
E141F
CPU # protocol
error. Power
cycle AC.
(continued)
Causes
A fatal system error
detected.
Specified processor is out
of acceptable temperature
range.
Specified processor is
missing or bad, and the
system is in an
unsupported
configuration.
Processors are in an
unsupported
configuration.
The system BIOS
has reported a processor
protocol error.
Corrective Actions
Check LCD for
additional scrolling
messages. Remove AC
power to the system for
10 seconds and restart the
system. If the problem
persists, see "Getting
Help" on page 181.
Ensure that the processor
heat sinks are properly
installed. See
"Troubleshooting the
Processors" on page 166
and "Troubleshooting
System Cooling
Problems" on page 156.
Ensure that the specified
microprocessor is
properly installed. See
"Troubleshooting the
Processors" on page 166.
Ensure that your
processors match and
conform to the type
described in the processor
technical specifications
outlined in your system's
Getting Started Guide.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 181.