Table 9. Power Usage Worksheet 2 - Intel SC5600LX - Server Chassis - Tower Service Manual

Server chassis
Table of Contents

Advertisement

Technical Reference
Device
Control Panel
Total Current
Worksheet, Total Combined Power Used by the Server
From the previous worksheet, enter the total current for each column.
Multiply the voltage by the total current to get the total wattage for each voltage level.
Add the total wattage for each voltage level to arrive at the total combined power usage for the power subsystem.
Voltage level and total current
(+3.3 V) X (______ A)
(+5 V) X (______ A)
(+12 V) X (______ A)
(–12 V) X (______ A)
(5 V standby) X (______ A)
Total Combined Wattage
CAUTION
Do not exceed a combined power output of 170 W for the +5 V and +3.3 V outputs. Exceeding a
combined 170 W will overload the power subsystem and may cause the power supplies to overheat
and malfunction.
60
Current (maximum) at voltage level
+3.3 V
+5 V

Table 9. Power Usage Worksheet 2

(V X A = W)
-5 V
+12 V
-12 V
Total watts for each voltage level
________ W
________ W
________W
________ W
________ W
________ W
Intel® Server Chassis SC5600 Service Guide
5 V Standby

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sc5600baseSc5600brpSc5600

Table of Contents