Start-Up Troubleshooting - U-Line CLR2060 Installation Manual

Echelon series clear ice maker
Hide thumbs Also See for CLR2060:
Table of Contents

Advertisement

4. Watch the water flow over the evaporator assembly (ice
cube tray) to familiarize yourself with the operation.
Upon initial start-up, water flow over the evaporator
may be uneven. This may cause uneven sized cubes or
water spilling into the ice storage bin. This is a normal
situation and will correct itself within the first 24 hours
of operation.
5. Replace the evaporator cover.
IMPORTANT
It is possible that dirt or scale will dislodge in the water
line. Always throw away all ice cubes made during the
first two to three hours of operation.
About Settings
All settings are factory preset. No adjustments should be
necessary at this time. For information about Ice Cube
Thickness, see the User Manual.
02/2005
CLR2060 — Clear Ice Maker

Start-Up Troubleshooting

Q:
Problem
Unit does not appear to turn on when switch is set to ICE.
A:
Solution
Remember that the compressor will not operate until the
water has been filling for about 3 minutes. Make sure unit
is plugged in and outlet has power (circuit breaker has
not tripped). If the unit is equipped with a drain pump,
check that the drain line is not obstructed — unit will shut
down due to the safety design of the pump if water
cannot drain.
Q:
Problem
Water does not appear to be flowing into unit.
A:
Solution
Check that the water is connected and turned on, the line
is not obstructed and the overflow tube is inserted
securely into water trough.
Q:
Problem
The unit has been operating for 24 hours and water is still
not flowing evenly over evaporator or ice seems slow to
release.
A:
Solution
Level unit for even water flow. Uneven water flow will
reduce ice rate and cause water to spill in ice bin.
See the User Manual's Troubleshooting Guide for more
solutions.