U-Line CLR2060 Installation Manual page 14

Echelon series clear ice maker
Hide thumbs Also See for CLR2060:
Table of Contents

Advertisement

To check and test hose connections:
1. Make certain the unit is not plugged into an electrical
outlet.
2. Carefully push the power cord grommet through the
hole in the back panel (see Figure 35).
Screws
Figure 35
3. Remove 12 screws and back panel.
WARNING
Back panel serves as a guard. DO NOT put your
hands inside the ice maker cabinet or attempt to
touch any components except the discharge tube
during testing. Failure to follow this warning
could result in serious personal injury or death.
4. Check that the clamps and hose connections are tight at
the following areas (see Figure 36):
• Discharge tube (A)
• Drain tube (B)
• Vent tube (C)
B
Back View
Figure 36
www.U-LineService.com
CLR2060 — Clear Ice Maker
Back
Panel
Drain
Fitting
Water
Connection
Grommet
Power
Cord
C
C
A
Side View
5. Place a suitable container beneath the pump's discharge
tube. (The bucket must be able to hold a minimum of
one gallon.)
6. Plug the ice maker power cord into a properly
grounded, polarized electrical outlet.
7. Verify pump operation by pouring one gallon of water
into the ice storage bin of the ice maker. The pump
should energize and pump the water into the container.
8. At this time, verify that all tube and clamp connections
are tight and leak free.
9. Unplug unit power cord from electrical outlet.
10. Reinstall back panel.
To connect to drain:
1. Attach the 5/8-inch ID drain connection on the back of
the unit to a 5/8-inch OD rigid tube, using a worm
clamp.
2. Attach the other end of the rigid tube to your 5/8-inch
ID drain line with a worm clamp.
3. Insulate the drain line, if necessary to prevent
condensation. Go on to Water Supply Connection.
Locally-Installed Drain Pump
If a gravity drain connection is not possible, and you have
not purchased the CLR2060 with factory-installed pump,
we strongly recommend the use of the U-Line P60 drain
pump. The U-Line P60 drain pump is available through
your Dealer, or direct from U-Line with complete
installation instructions. If a pump other than the U-Line
P60 drain pump is to be used, it must meet the following
specifications:
• It must be UL listed and have a UL listed, 120 VAC,
3-wire grounded power cord.
• It must have overall maximum outside dimensions of
8-3/4" wide x 5-3/4" deep x 7-3/4" high.
• It must have a minimum flow rate of 15 gallons per
B
hour at 10 feet of lift.
• It must have a sealed sump which does not allow water
leakage in the case of a power outage, restricted drain
or pump failure.
• It must have a check valve in the discharge line to
prevent waste water return to the pump.
• It must have an overflow protection control which will
shut off power to the ice maker in the event of a pump
failure.
• It must have an operating temperature range of 50°F
to 110°F (10°C to 40°C).
14
02/2005

Advertisement

Table of Contents
loading

Table of Contents