Troubleshooting System Memory - Dell POWEREDGE R805 Hardware Owner's Manual

Dell server user manual
Hide thumbs Also See for POWEREDGE R805:
Table of Contents

Advertisement

4 Ensure that the faulty fan is fully seated in the fan bracket and attached to
the power connector. See "System Fans" on page 82.
NOTE:
whether it is working properly.
5 If the problem is not resolved, install a new fan. See "System Fans" on
page 82.
If the replacement fan is working properly, close the system. See "Opening
and Closing the System" on page 70.
If the replacement fan does not operate, see "Getting Help" on page 175.

Troubleshooting System Memory

Problem
Faulty memory module.
Faulty system board.
Front-panel status LCD indicates a problem with system memory.
Action
CAUTION:
cover and access any of the components inside the system. Before performing any
procedure, see your Product Information Guide for complete information about
safety precautions, working inside the computer and protecting against
electrostatic discharge.
1 If the system is operational, run the appropriate online diagnostic test. See
"Using Server Administrator Diagnostics" on page 161.
If diagnostics indicates a fault, follow the corrective actions provided by
the diagnostic program. If the problem is not resolved or if the system is
not operational, continue to the next step.
2 Turn off the system and attached peripherals, unplug the system from the
power source and press the power button, and then reconnect the system
to power.
150
Troubleshooting Your System
Wait 30 seconds for the system to recognize the fan and determine
Only trained service technicians are authorized to remove the system

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents