Table 1-6. LCD Status Messages
Code
Text
N/A
SYSTEM NAME
E1000 FAILSAFE,
Call Support
E1114 Temp Ambient Ambient system
E1118 CPU Temp
Interface
E1210 CMOS Batt
E1211 ROMB Batt
E1214
## PwrGd
E1216
E1217
Causes
A 62-character string that
can be defined by the user in
the System Setup program.
The SYSTEM NAME
displays under the following
conditions:
• The system is powered on.
• The power is off and
active errors are displayed.
Check the system event log
for critical failure events.
temperature is out of
acceptable range.
The BMC is unable to
determine the CPU(s)
temperature status.
Consequently, the BMC
increases the CPU fan speed
to maximum
as a precautionary measure.
CMOS battery is missing, or
the voltage is out of
acceptable range.
RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.
Specified voltage regulator
has failed.
Corrective Actions
This message is for
information only.
You can change the
system ID and name in
the System Setup
program. See "Using the
System Setup Program"
on page 47.
See "Getting Help" on
page 175.
See "Troubleshooting
System Cooling
Problems" on page 149.
Turn off power to the
system and restart the
system. If the problem
persists, see "Getting
Help" on page 175.
See "Troubleshooting the
System Battery" on
page 147.
Reseat the RAID battery
connector. See "RAID
Battery" on page 87, and
"Troubleshooting System
Cooling Problems" on
page 149.
See "Getting Help" on
page 175.
About Your System