Dell POWEREDGE R805 Hardware Owner's Manual page 43

Dell server user manual
Hide thumbs Also See for POWEREDGE R805:
Table of Contents

Advertisement

Table 1-7. System Messages (continued)
Message
Time-of-day not
set - please run
SETUP program
Timer chip
counter 2 failed
Unsupported CPU
combination
Unsupported CPU
stepping
detected
TPM failure
Utility
partition not
available
Warning:
Following faulty
DIMMs are
disabled:
DIMM n
n
1
2
Total memory size
is reduced.
Warning: A fatal
error has caused
system reset!
Please check the
system event log!
Causes
Incorrect Time or Date
settings; faulty system
battery.
Faulty system board.
Microprocessor(s) is not
supported by the system.
A Trusted Platform Module
(TPM) function has failed.
The <F10> key was pressed
during POST, but no utility
partition exists on the boot
hard drive.
Faulty or improperly seated
memory module(s). DIMMs
are disabled in pairs, as
indicated by the n
1
Check both DIMMs for a
possible fault.
A fatal system error occurred
and caused the system to
reboot.
Corrective Actions
Check the Time and Date
settings. See "Using the
System Setup Program" on
page 47. If the problem
persists, replace the system
battery. See "System Battery"
on page 125.
See "Getting Help" on
page 175.
Install a supported
microprocessor or
microprocessor combination.
See "Processors" on page 120.
See "Getting Help" on
page 175.
Create a utility partition on
the boot hard drive. See the
CDs that came with your
system.
See "Troubleshooting System
Memory" on page 150.
and n
.
2
Check the SEL for
information that was logged
during the error. See the
applicable troubleshooting
section in "Troubleshooting
Your System" on page 137 for
any faulty components
specified in the SEL.
About Your System
43

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents