Table 1-6. LCD Status Messages (continued)
Code
Text
E141F CPU Protocol The system BIOS has
E1421 CPU Init
E1422 CPU Machine
Chk
E1610 PS # Missing No power is available from
E1614 PS # Status
E1618 PS #
Predictive
E161C PS # Input
Lost
E1620 PS # Input
Range
Causes
reported a processor
protocol error.
The system BIOS has
reported a processor
initialization error.
The system BIOS has
reported a machine check
error.
the specified power supply;
specified power supply is
improperly installed or
faulty.
No power is available from
the specified power supply;
specified power supply is
improperly installed or
faulty.
Power supply voltage is out
of acceptable range;
specified power supply is
improperly installed or
faulty.
Power source for specified
power supply is unavailable,
or out of acceptable range.
Power source for specified
power supply is unavailable,
or out of acceptable range.
Corrective Actions
See "Getting Help" on
page 175.
See "Getting Help" on
page 175.
See "Getting Help" on
page 175.
See "Troubleshooting
Power Supplies" on
page 147.
See "Troubleshooting
Power Supplies" on
page 147.
See "Troubleshooting
Power Supplies" on
page 147.
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supplies" on page 147.
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supplies" on page 147.