Dell POWEREDGE R805 Hardware Owner's Manual page 30

Dell server user manual
Hide thumbs Also See for POWEREDGE R805:
Table of Contents

Advertisement

Table 1-6. LCD Status Messages (continued)
Code
Text
E1811 HDD ## Rbld
Abrt
E1812 HDD ##
Removed
E1914 DRAC5 Conn2
Cbl
E1915 IO55 HTSink
Missing
MCP55 Htsink
Missing
E1A12 PCI Rsr
Missing
E1A14 SAS Cable A
E1A15 SAS Cable B
E1A1C LOM Mezz
Missing
30
About Your System
Causes
The specified hard drive has
experienced a rebuild abort.
The specified hard drive has
been removed from the
system.
DRAC 5 cable is missing or
disconnected.
Heatsink sensor reports that
the chipset IO55 heatsink is
missing.
Heatsink sensor reports that
the chipset MCP heatsink
heatsink is missing.
One or all of the PCIe risers
is missing, preventing the
system from powering on.
SAS cable A is missing or
bad.
SAS cable B is missing or
bad.
LOM daughter card is
missing.
Corrective Actions
See "Troubleshooting a
Hard Drive" on page 155.
If the problem persists,
see your RAID
documentation.
Information only.
Reconnect the cable. See
"Installing a RAC Card"
on page 106.
See "Getting Help" on
page 175.
Reinstall the missing riser
card(s).
Reseat the cable. If the
problem persists, replace
cable. See "SAS
Controller Daughter
Card" on page 84.
Reseat the cable. If the
problem persists, replace
cable. See "SAS
Controller Daughter
Card" on page 84.
Install or reseat the LOM
daughter card. If the
problem persists, replace
the card. See "Getting
Help" on page 175.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents