Dell POWEREDGE R805 Hardware Owner's Manual page 32

Dell server user manual
Hide thumbs Also See for POWEREDGE R805:
Table of Contents

Advertisement

Table 1-6. LCD Status Messages (continued)
Code
Text
E201C SMI Init
E201D Shutdown Test BIOS shutdown test failure. See "Getting Help" on
E201E POST Mem Test BIOS POST memory test
E201F DRAC Config
E2020 CPU Config
E2021 Memory
Population
E2022 POST Fail
E2110 MBE DIMM # &
#
32
About Your System
Causes
System management
interrupt (SMI)
initialization failure.
failure.
Dell remote access
controller (DRAC)
configuration failure.
CPU configuration failure.
Incorrect memory
configuration. Memory
population order incorrect.
General failure after video.
One of the DIMMs in the
set implicated by "# & #"
has had a memory multi-bit
error (MBE).
Corrective Actions
See "Getting Help" on
page 175.
page 175.
See "Troubleshooting
System Memory" on
page 150. If problem
persists, see "Getting
Help" on page 175.
Check screen for specific
error messages.
Ensure that DRAC cables
and connectors are
properly seated. If
problem persists, see your
DRAC documentation.
Check screen for specific
error messages.
Check screen for specific
error messages. See
"Troubleshooting System
Memory" on page 150.
Check screen for specific
error messages.
See "Troubleshooting
System Memory" on
page 150.