Table 1-7. System Messages
Message
Alert! Node
Interleaving
disabled! Memory
configuration
does not support
Node
Interleaving.
Attempting to
update Remote
Configuration.
Please wait...
BIOS Update
Attempt Failed!
Caution!
NVRAM_CLR jumper
is installed on
system board.
CPUs with
different cache
sizes detected!
Decreasing
available memory
36
About Your System
Causes
The memory configuration
does not support node
interleaving, or the
configuration has changed
(for example, a failed
DIMM) so that node
interleaving cannot be
supported. The system will
run but with reduced
functionality.
Remote Configuration
request has been detected
and is being processed.
Remote BIOS update
attempt failed.
NVRAM_CLR jumper is
installed. CMOS has been
cleared.
Microprocessors with
different cache sizes are
installed.
Faulty or improperly installed
memory modules.
Corrective Actions
Ensure that the memory
modules are installed in a
configuration that supports
node interleaving. Check
other system messages for
additional information for
possible causes. For memory
configuration information,
see "General Memory
Module Installation
Guidelines" on page 114. If
the problem persists, see
"Troubleshooting System
Memory" on page 150.
Wait until the process is
complete.
Retry the BIOS update. If
problem persists, see
"Getting Help" on page 175.
Remove NVRAM_CLR
jumper. See Figure 6-1 for
jumper location.
Ensure that all
microprocessors have the
same cache size and that
they are properly installed.
See "Processors" on page 120.
See "Troubleshooting System
Memory" on page 150.