4
Command Line Interface
Command Usage
When set to receive all frame types, any received frames that are untagged
are assigned to the default VLAN.
Example
The following example shows how to restrict the traffic received on port 1 to tagged
frames:
Console(config)#interface ethernet 1/1
Console(config-if)#switchport acceptable-frame-types tagged
Console(config-if)#
Related Commands
switchport mode (4-155)

switchport ingress-filtering

This command enables ingress filtering for an interface.
Note:
Although the ingress filtering command is available, the switch has ingress filtering
permanently set to enable. Therefore, trying to disable the filtering with the "no
switchport ingress-filtering" command will produce this error message: "Note:
Failed to ingress-filtering on ethernet interface !"
Syntax
switchport ingress-filtering
Default Setting
Enabled
Command Mode
Interface Configuration (Ethernet, Port Channel)
Command Usage
• Ingress filtering only affects tagged frames.
• With ingress filtering enabled, a port will discard received frames tagged for
VLANs for it which it is not a member.
• Ingress filtering does not affect VLAN independent BPDU frames, such as
GVRP or STA. However, they do affect VLAN dependent BPDU frames, such
as GMRP.
Example
The following example shows how to set the interface to port 1 and then enable
ingress filtering:
Console(config)#interface ethernet 1/1
Console(config-if)#switchport ingress-filtering
Console(config-if)#