SMC Networks 6724L2 - annexe 1 Management Manual page 44

24-port fast ethernet switch
Hide thumbs Also See for 6724L2 - annexe 1:
Table of Contents

Advertisement

C
I
ONSOLE
NTERFACE
Parameter
Flow Control Off
Jack Type
2-30
Default Description
Used to enable or disable flow control. Flow
control can eliminate frame loss by
"blocking" traffic from end stations or
segments connected directly to the switch
when its buffers fill. When enabled, back
pressure is used for half duplex and IEEE
802.3x for full duplex. Note that flow control
should not be used if a port is connected to
a hub. For the Gigabit modules the options
for flow control are set out below:
Switch
SendOnly Rcv/BothWay Switch can only
BothWay Rcv/BothWay Both switch and
* SMC6724L2 or SMC6724L3
Shows the jack type for each port.
Ports 1-24: RJ-45
Ports 25-26: SC, RJ-45
Link Partner* Flow Control
send pause
frames, link
partner can only
receive pause
frames.
link partner can
send and receive
pause frames.