MSI MS-9246 User Manual page 22

1u rackmount server
Hide thumbs Also See for MS-9246:
Table of Contents

Advertisement

M SI Server M anagement IPM I 1.5 (optional)
u MSI-9569 BMC card (with QLogic Zircon UL BMC) and MSI iConsole AP support
IPMI 1.5 (option)
MS-9569 BMC Card Specification
BM C Chip
- Qlogic Zircon UL ( ARM7 TDMI 32-bit/40MHz RISC), 128-pin PQFP
- Host hardware interface: LPC interface
- Host software interface: KCS interface
M emory Size
- 256 X 16 Bits SRAM
- 4M Bits Flash
Form Factor
- Add-on Card on CN7 SO-DIMM (144 pin, Key position in 50)
Onboard I2Cmux
-
9545
Onboard Connector/Header
- JTAG header (14 pin) for debugging
Key Features
- IPMI 1.5 Compliant
- Out-of-band LAN based management using RMCP
- FRU/SEL access
- Remote out-of-band alerts
- Event log
- Support for CLI (command line interface) over Serial or shared NIC (RMCP)
- Ability to update firmware inband unattended
- Remote access security (MD5)
- Out-of-band environmental monitoring and alerting
- Secure remote power control and system reset over Serial or shared NIC
(RMCP)
- Support Microsoft EMS
- Support onboard I2C ADT 7463, W inbond 83791 to extend Hardware monitor
feature
- Support ASR (Automatic Server Re-start)
Sy stem M anagement
Two SMBus 2.0 (I2C)
- One SMBus for Intel 82546GB
- One SMBus for ADT 7463, W inbond 83791, SEEPROM access, CPU thermal
sens or
CPU Fan speed control dependent on System Temperature
System Fan speed control dependent on System Temperature
Sensor M anagement
Monitored Voltage: +5V, +3.3V, Vcore
Thermal protection (CPU/System overheat shut down through BMC)
No Chassis Intrusion
LED x 3 (ID_LED, BMC Heartbeat, Status LED )