2.1.13 PoE status and command operation
Some status definition described below before you read or execute the command,
Non-PD,
this means there is an ethernet device but not PD device is loaded
No Load:
there is not any PD device being loaded to that port, but non-PD may be
Loaded:
a PD device is being loaded, class level and allocated power is shown
PD Error:
over current event ( exceed 350 ma ) happened, and port is disabled automatically
Dedicated class,
Allocated power,
display the class level of current loaded PD device
maximum allocated power to that port , but not current power
PoE Port Configuration
Port PSE Power
Enable
1
Enable
2
Disable
3
Enable
4
Enable
5
Enable
6
Enable
7
Enable
8
System Max. Supplied Power (A)
Total Allocated Power (B)
Power Balance (C = A - B)
IEEE 802.3af Class - Power Table
IEEE 802.3af Class
PSE Output Power 15W 4W
Detected
Allocated
Class
Power
3
15 W
N/A
0 W No Load
3
0 W PD Error
N/A
0 W No Load
N/A
0 W No Load
N/A
0 W No Load
N/A
0 W No Load
N/A
0 W Non-PD
Apply
Refresh
0
1
2
3
7W 15W Reserved
24
PoE
Status
Loaded
120 Watt
15 Watt
105 Watt