Advanced Entry Calibration (continued)
Step
Operator Action
16
Press the
Key.
Using the
or the
FWD
Key, set the 'Paper' level to the
value determined in the
previous step. Press the
Key to set the entry (indicated
by the '*') and advance the
menu.
Repeat for the 'Gap' (or
'Mark') and 'Empty' levels.
17
After all entries have been
made, press the
back out of the menu and then
press the
Key to save
the settings and return to the
Ready Mode.
Note: If the Advanced Entry Calibration fails, try the following procedure.
Re-enter Media Settings / Calibration / Advanced Entry / Sensor Gain and lower the selected Gain Setting number by one (to
make the sensor less sensitive). Select the new Gain Setting, save the changes, exit the menu, and then test your media.
Repeat the procedure until a usable media setting is obtained.
M-Class
Displayed Message
!
QBQFS!TFOTPS!MFWFM!
Q+2:9!H+195!F+125!
!
!
REV
HBQ!TFOTPS!MFWFM!
Q+2:9!H+195!F+125!
!
!
FNQUZ!TFOTPS!MFWFM!
Q+2:9!H+195!F+125!
!
!
!
!
Or, for reflective media:
!
QBQFS!TFOTPS!MFWFM!
Q+126!N+292!F+324!
!
!
NBSL!TFOTPS!MFWFM!
Q+126!N+292!F+324!
!
!
FNQUZ!TFOTPS!MFWFM!
Q+126!N+292!F+324!
!
TBWF!DIBOHFT@!
FOUFS!LFZ!>!ZFT!
Key to
!
!
!
Comment
The selection will flash and the display heading will
change to indicate the item for entry.
From 'Ready', press the FEED Key to advance to
the next label TOF.
77