3.6.2 Survey Software

The Survey Software menu enables you to align antennas and to assess the radio
signal quality of a point-to-point link. The sub-menu includes the following
options:
Operation Mode – When running a Site Survey, set the units on either side of
the link to either receive (option 1) or transmit (option 2) packets (one unit
should be set to transmit and the other to receive).
Start Statistics – Type 2 and then press any digit to start Site Survey.
Stop Statistics – Type 3 and then press any key to stop update of Site Survey
statistics.

3.6.3 Using the Site Survey Software

1. Roughly align the antennas on either side of the link before starting the Site
Survey procedure.
2. Verify that the Ethernet cables are disconnected from both units.
3. Type 1 to access the Operation mode screen. Set the units on either side of the
link to either receive (option 1) or transmit (option 2) packets (one unit should
be set to transmit and the other to receive).
4. Start the survey by selecting option (2) in the Survey Software menu in both
units. When performing a site survey from a station to an AP (transmitting from
the station to the AP), always begin with the station (select option (2) on the
station).
5. On the transmit side, a screen appears displaying a table with the number of
packets and the frequency at which each packet was transmitted. This list is
updated continuously. Select option (3) to stop sending packets.