external antennas and RF cable. For information regarding external antenna
installation, refer to Section 5.3.
Keep the units well away from sources of heat, such as radiators and air-
conditioners.
2.3.1 Additional Considerations When Positioning the Access
Point
When positioning the AP-10 PRO.11 and AP-10DE Access Points, take into
account the following additional considerations.
Install the Access Point at least 1.5m above the floor, clear of any high office
partitions or tall pieces of furniture in the coverage area. The Access Point can be
placed on a high shelf, or can be attached to the ceiling or a wall using a mounting
bracket.
Install the Access Point in a central location in the intended coverage area. Good
positions are:
In the center of a large room
In the center of a corridor
At the intersection of two corridors
Many modern buildings have partitions constructed of metal or containing metal
components. We recommend that you install the Access Points on the corridor
ceilings. The radio waves propagated by the BreezeNET PRO.11 LAN are reflected
along the metal partitions and enter the offices through the doors or glass sections.