Omron ZFX-C Command Reference Manual page 57

Smart sensor
Hide thumbs Also See for ZFX-C:
Table of Contents

Advertisement

Position shift correction parameters
2 model search
Data No.
Parameter
51
Search mode
53
Rotation range
54
Skipping angle
55
Interpolation
56
Verification
57
Candidate level
71
Correlation upper limit value
72
Correlation lower limit value
73
X upper limit value
74
X lower limit value
75
Y upper limit value
76
Y lower limit value
77
Angle upper limit value
78
Angle lower limit value
ZFX-C Serial Communication Command Reference
Output Range
0: Hi-speed, 1: Normal, 2: Precision
0 to 180
0: 1°, 1: 2°, 2: 3°, 3: 5°, 4: 10°, 5: 15°, 6: 20°,
7: 30°
0: OFF, 1: ON
0: OFF, 1: ON
0 to 100
0 to 100
0 to 100
-9999.999 to 9999.999
-9999.999 to 9999.999
-9999.999 to 9999.999
-9999.999 to 9999.999
-180 to 180
-180 to 180
About Communication Commands
55

Advertisement

Table of Contents
loading