Re-registering the Model of the Specified Item < MODELSET command >
This command re-registers the model of the specified item. It does not reset filters, etc.
Important
The execution of this command does not re-register any model for the flexible search, graphic search and grouping
items.
< Command format >
M O D E
L S E T
< Response format >
When processing ends successfully
O K
C R
When processing fails
C R
E R
< Explanation of parameters >
Measurement item No.
Attribute
18
About Communication Commands
or
C R
Attribute
Measurement
item No.
(max. 3 digits)
Specifies the measurement item No.
Measurement items: 0 to 127 (ZFX-C20/C25/C10H/C15H), 0 to 31 (ZFX-C10/C15)
Position correction items: 0 to 3
0: Position correction 0 of camera 0
1: Position correction 1 of camera 0
2: Position correction 0 of camera 1
3: Position correction 1 of camera 1
Specifies measurement item or position correction item.
0: Measurement item
1: Position correction item
Default is measurement item.
M S
C R
Attribute
Measurement
item No.
(max. 3 digits)
ZFX-C Serial Communication Command Reference