Omron ZFX-C Command Reference Manual page 53

Smart sensor
Hide thumbs Also See for ZFX-C:
Table of Contents

Advertisement

Edge inspection parameters
Position
Data No.
Parameter
51
Measurement mode
52
Color mode
53
Split size
54
Color
55
Edge level
56
Noise level
57
Noise width
58
Calibration
59
Coordinates mode
71
X upper limit value
72
X lower limit value
73
Y upper limit value
74
Y lower limit value
Width
Data No.
Parameter
51
Measurement mode
52
Color mode
53
Split size
54
Color1
55
Edge level1
56
Noise level1
57
Noise width1
58
Color2
59
Edge level2
60
Noise level2
61
Noise width2
62
Calibration
63
Coordinates mode
71
Edge width upper limit value
72
Edge width lower limit value
73
Edge position X1 upper limit value
74
Edge position X1 lower limit value
75
Edge position Y1 upper limit value
76
Edge position Y1 lower limit value
77
Edge position X2 upper limit value
78
Edge position X2 lower limit value
79
Edge position Y2 upper limit value
80
Edge position Y2 lower limit value
ZFX-C Serial Communication Command Reference
Output Range
0:Average, 1: Peak, 2: Bottom
0: Color filter, 1: Color Pickup
1 to 99
0: Light → Dark, 1: Dark → Light
1 to 99
0 to 255
0 to 255
0: OFF, 1: ON
0: Normal, 1: Pos. correction
-9999.999 to 9999.999
-9999.999 to 9999.999
-9999.999 to 9999.999
-9999.999 to 9999.999
Output Range
0: Average, 1: Maximum, 2: Minimum
0: Color filter, 1: Color Pickup
1 to 99
0: Light → Dark, 1: Dark → Light
1 to 99
0 to 255
0 to 255
0: Light → Dark, 1: Dark → Light
1 to 99
0 to 255
0 to 255
0: OFF, 1: ON
0: Normal, 1: Pos. correction
0.000 to 9999.999
0.000 to 9999.999
-9999.999 to 9999.999
-9999.999 to 9999.999
-9999.999 to 9999.999
-9999.999 to 9999.999
-9999.999 to 9999.999
-9999.999 to 9999.999
-9999.999 to 9999.999
-9999.999 to 9999.999
About Communication Commands