BASIC commands
Example

DEVICENET (0,2,1,10,16,150,31)

In this example, the TJ1-DRT is configured to exchange data with DeviceNet
master with 16 output words (received from the master) located at VR(10) to
VR(25), and 31 input words (sent to the master) located at VR(150) to
VR(180).
See also
N/A
/i
PROGRAMMING MANUAL
Bit
Value
Description
0
0
DEVICENET (unit_number, 2, ...) not executed yet
1
DEVICENET (unit_number, 2, ...) executed without error
1
0
No DeviceNet I/O connection
1
DeviceNet I/O connection running
2
0
VR variables in the output data range have been updated
1
VR variables in the output data range have not been updated yet
3
0
DeviceNet I/O connection size matches the DEVICENET
(unit_number, 2,...) command
1
DeviceNet I/O connection size does not match the
DEVICENET(unit_number, 2,...) command
4-7
0
Always zero
8
0
Network power OK
1
Network power failure
9
0
No BUSOFF occurred
1
BUSOFF occurred
10
0
No node address duplication error
1
Node address duplication error