System_Error; T_Ref - Omron TJ1-MC04 - PROGRAMMING 1 Programming Manual

Hide thumbs Also See for TJ1-MC04 - PROGRAMMING 1:
Table of Contents

Advertisement

BASIC commands

3.2.254 SYSTEM_ERROR

/i
Type
System parameter (read only)
Syntax
SYSTEM_ERROR
Description
The SYSTEM_ERROR parameter contains system errors that occurred in the
TJ1 system since the last time it was initialized. The bits in the
SYSTEM_ERROR parameter are given in the table below.
Arguments
N/A.
Example
No example.
See also
N/A
/i
Bit
0
BASIC error
1
Battery low error
2 - 7
Reserved for future use
8
Configuration unit error (Any unit in the system)
9
Configuration device error (Any device in the system)
10 - 15
Reserved for future use
16
Unit lost error (Any unit in the system)
17
Terminator not fitted
18
Device lost error (Any device in the system)
PROGRAMMING MANUAL
Description

3.2.255 T_REF

/i
Type
Axis parameter
Syntax
T_REF
DAC
Description
The T_REF parameter contains the torque reference value which will be
applied to the servo motor. The range of this parameter is defined by the
number of available bits. For MECHATROLINK axes, T_REF takes 32 bits, so
the available range is [-2147483648, 2147483648], which corresponds to a
voltage range [-10V, 10V]. For Flexible axis axes, T_REF takes 16 bits, so
available range is [-32768, 32767], which corresponds to a voltage range [-
10V, 10V]. These ranges can be limited by using the OUTLIMIT parameter.
The actual torque reference is depending on the servo motor.
Arguments
N/A
Example
T_REF AXIS(0)=1000
See also
AXIS, S_REF.
142

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tj1-mc16 - programming 1Tj1-mc04 1

Table of Contents