E-4 Explicit Message Error Codes - Omron MX2 COMPONET OPTION BOARD User Manual

Mx2 componet option board
Table of Contents

Advertisement

Explicit Message Error Codes
E-4
Explicit Message Error Codes
When an error response has been returned for the executed explicit message,
this response will have the following format.
00
No. of bytes
received node address
Within the frame, one of the following error codes will be included.
Table E-5 Error Response
Response
Error Name
Code
02@@
Resource unavailable
08@@
Service not supported
09@@
Invalid attribute value
0C@@
Object state conflict
0E@@
Attribute not settable
10@@
Device state conflict
13@@
Not enough data
14@@
Attribute not supported
15@@
Too much data
16@@
Object does not exist
1F@@
Vendor specific
20@@
Invalid parameter
06
00
94
Source
Service
Code
An internal communication error between
Option Board and Inverter
The service code is incorrect.
The specified attribute / inverter parame-
ter value is not supported. The data writ-
ten is outside range.
The specified command cannot be exe-
cuted due to an internal error.
An attribute ID supported only for reading
has been executed for a write service
code.
The specified command cannot be exe-
cuted in this inverter mode.
The data is smaller than the specified
size (accessing only high word of double
word).
The attribute or inverter parameter does
not exists.
The data is larger than the specified size
(accessing single word with double word
data).
The specified Instance ID is not sup-
ported.
This code is returned in case of an
Inverter error.
The specified operation command data is
not supported.
Appendix E
Error Code
Cause
71