Operating Procedures; Flow Of Operation - Omron H8PS Manual

Cam positioner
Hide thumbs Also See for H8PS:
Table of Contents

Advertisement

Operating Procedures

■ Flow of Operation

Initial Settings
Setting Resolution and
Rotation Direction
Setting the Origin
Advanced
Setting Functions
function
Programming Cams (Programming Mode)
Setting ON/OFF Angles
Setting the ADV Function
Checking Timing (Test Mode)
Operation (Run Mode)
Checking ON/OFF Angle Settings
Clearing Settings
■ Settings for Basic Functions
Changing the Mode
PRG
Programming Mode
TST
RUN
Changed with the mode switch.
PRG
TST
Test Mode
RUN
Changed with the mode switch.
PRG
Run Mode
TST
RUN
Key
ADV
5 s min.
All Protection
Disables all keys
and switches.
will light when the all
protection function is
enabled.
Refer to page 24.
20
Cam Positioner
The Encoder resolution and rotation direction is set on a DIP switch.
➾ For details on the setting methods, refer to page 21.
The Encoder is mounted to the machine and the origin for operation is determined.
➾ For details on the setting methods, refer to page 21.
Parameters can be set in Function Setting Mode to perform more advanced operations.
➾ For details, refer to page 26 Advanced Functions.
There are three methods that can be used to set or change ON/OFF angles (i.e., cam programming).
Using the ANGLE Keys (Manual Mode)
Actually turning the Encoder (Teaching Mode)
Setting from personal computer using Support Software (order separately)
➾ For details on the setting methods, refer to pages 22 to 23.
Advance angle compensation (ADV) function can be set if required.
Advanced
➾ For details on the setting methods, refer to page 27.
function
The machine is operated and outputs are actually made to check the timing of operation.
If the timing of operation is not correct, it can be changed.
➾ For details, refer to page 23.
Operation is started.
➾ For details, refer to page 24.
The ON/OFF angles that have been set can be checked.
➾ For details, refer to page 24.
Deletes settings. There are two methods that can be used to delete settings.
Clearing all programs (deletes all programming)
Clearing individual steps, cams, and banks
➾ For details, refer to page 25.
PRG
TST
RUN
ON/OFF
Key
1 s min.
Switching the Angle
and Speed Display
Main Display: Angle
Sub-display: Speed
Main Display: Speed
Sub-display: Angle
Refer to page 24.
H8PS
Programming Mode
Used to write cam programs, set the advance angle compensation
function, etc.
All outputs will remain OFF.
Test Mode
Used to write cam programs, set the advance angle compensation
function, and perform other operations while actually turning ON
outputs to confirm operation timing. This mode is also used to adjust
settings during operation.
Run Mode
Used for normal operation. Settings, such as writing cam programs
and setting the advance angle compensation function, cannot be