■ Advanced Functions

Set the advanced functions as required to perform more advanced operation. Outlines of the advanced functions are provided on the following
pages. For details, refer to the Operation Manual (Cat. No. Z199).

Mode Transitions

PRGM
TEST
Programming Mode
RUN
Changed with the mode switch.
PRGM
TEST
Test Mode
RUN
Changed with the mode switch.
PRGM
TEST
Run Mode
RUN
ADV Key 5 s min.
All Protection
Disables all keys
and switches.
will light when the all
protection function is
enabled.
Refer to page 24.
26
Cam Positioner
ADV Key 3 s min.
PRG
TST
RUN
ON/OFF Key 1 s min.
Switching the Angle
Setting the
and Speed Display
ADV Function
Main Display: Angle
Advance angle
compensation (ADV)
Sub-display: Speed
function automatically
advances the ON/OFF
Main Display: Speed
angle of outputs in
Sub-display: Angle
proportion to the
machine (Encoder)
Refer to page 24.
speed.
H8PS
The values in parentheses are the default settings.
Function Setting Mode
Refer to pages 28 to 30.
: No. of pulse outputs [60]
ADV Key
: Pulse output start angle [0 ]
ADV Key
: Speed alarm upper limit [---]
ADV Key
: Speed alarm lower limit [---]
ADV Key
ADV Key
: Step number limit [---] (See note 1.)
ADV Key
: Cam protection [None]
ADV Key
: Bank enable/disable [Disable]
ADV Key
: Bank switching method [Bank inputs] (See note 2.)
ADV Key
: Bank copy (See note 2.)
ADV Key
: E24 detection enable/disable [Enable]
ADV Key
Shaded items above are not displayed for 8-output models.
Note 1: The default setting is for 10 steps for all cams.
Note 2: Not displayed when F7 is disabled.