Operation (Run Mode)
Starting Operation
Set the mode switch to RUN to start operation.
Mode
PRGM
TEST
RUN
1
2
7
Start input
indication
(See note.)
STEP
CAM
Note: For 16/32-output models, be sure that the start input is
ON and that the start input indicator is lit. Outputs
(including the cam, pulse, and run outputs) will not
function if the start input is OFF. The 8-output models do
not have a start input.
Switching the Angle and Speed Displays
Press the
Key for at least 1 s in Run Mode to reverse
ON
OFF
the display positions of the present angular position and speed (r/min)
between main display and sub-display.
1
2
7
RUN
Press the
ON
1
2
7
RUN
24
Cam Positioner
RUN
Present angular position
Speed (r/min)
Present angular position on main display
Speed (r/min) on sub-display
Key for 1 s min.
OFF
Speed (r/min) on main display
Present angular position on sub-display
H8PS
All Protection Function
The all protection function locks the H8PS in Run Mode and prohibits
any changes to settings. It can be used to prevent incorrect or
unauthorized operation. If the
Run Mode, the All Protection indicator
and all keys and switches will be disabled. If the mode switch is
changed to Programming or Test Mode while protection is enabled,
the All Protection indicator
cannot be changed. If a setting on the DIP switch is changed while
protection is enabled, the All Protection indicator
the power supply is turned ON to indicate that settings cannot be
changed.
All Protection Function Disabled (Normal Operation)
1
2
4
5
6
RUN
STEP
CAM
Press the
Key for 5 s min.
ADV
All Protection Function Enabled
1
2
4
5
6
RUN
CAM
STEP
Checking ON/OFF Angle Settings
• During Run Mode, the CAM Keys
can be used to check the ON/OFF angle settings for any step. Also,
the
Key can be pressed to check the ON/OFF angle
CHECK
settings in order for all steps starting from cam 1. If there is no key
operation for 10 s or longer during the checking operation, the
previous display will be resumed.
Key is pressed for at least 5 s in
ADV
will light on the display
will flash to indicate that settings
will flash when
All protection indication
and STEP Keys