Basic Operation

4-1

Basic Operation

Step 1: Start the Face
Plate Auto-Builder for
NS
Step 2: Make the
Required Settings
16
Start the Face Plate Auto-Builder for NS by selecting Programs\OMRON\CX-
One/Face Plate Auto-Builder for NS\Face Plate Auto-Builder for NS from
the Windows Start Menu. The following parameter setting screen will be dis-
played, when the Face Plate Auto-Builder for NS starts.
CSV Tag File
Set the folder location and file name of the CSV tag file from which the project
will be built. Click the Browse (1) Button to display a dialog box for selecting
the CSV tag file.
Project Name
Set the name of the CX-Designer project file to be created (up to 38 charac-
ters).
Output Folder
Set the folder that will output the CX-Designer project file. Click the Browse
(2) Button to display a dialog box for selecting the folder that will output the
project.
■ Build Conditions
PT Model/Project Version
Select the model of the NS-series PT and the system version.
Model
NS7
NS System Version 2
NS8
NS System Version 4 or Version 6.6
NS10
NS System Version 2
NS System Version 4 or Version 6.6
NS12 (Default) NS System Version 2
NS System Version 4 or Version 6.6
NS-Runtime
NS System Version 6.6
Project version
(system version)
Section 4-1
Number of changeable
function blocks
32
100 (See note.)
32
100 (See note.)
32
100 (See note.)
100 (See note.)