Batch Flowrate Capture (Block Model 014)
12: PAUSE Button
This button specifies the interrupt (pause) command. When this button is
touched, the write address of tag ITEM S2 is set to 1. The value of tag ITEM
S2 is referenced to set the display color, as shown in the following table.
Display color
Yellow
0
Red
1
The button is built as a momentary ON/OFF Button using a Simple Rectangle
(Type 2). The write address is not set, and the read address for tag ITEM S2 is
set as display address 1. The label displays "PAUSE" in the rough font.
The following macro is set as a Touch OFF Timing macro, and when touched,
the fixed value 1 is written to the write address of tag ITEM S2.
$B32766=1;
WRITECMEM([S2],$B32766,1
The following diagram shows a Batch Flowrate Capture Block face plate built
using the Face Plate Auto-Builder for NS in a 640×480 screen resolution.
The whole face is built using 458×142 dots.
The display and operation of each object in the face plate is the same as the
version for 800×600 screen resolution.
S2 (037)
Section 6-18
111