Sixteen-Point Output Units (E-Con Connectors) - Omron CRT1 - 10-2009 Operation Manual

Componet slave units and repeater unit
Table of Contents

Advertisement

Units with Connectors
5-4-4

Sixteen-point Output Units (e-CON Connectors)

CRT1-OD16S/CRT1-OD16S-1/CRT1-OD16SH/CRT1-OD16SH-1
Output Section Specifications
Item
Model
I/O capacity
Internal I/O common
Rated output current
Residual voltage
Leakage current
ON delay
OFF delay
Load short-circuit
detection
Disconnection detec-
tion
Number of circuits per
common
Isolation method
Output indicators
Installation
Power supply type
Current supplied to out-
put devices
Communications power
supply current con-
sumption
I/O power supply cur-
rent consumption
Output handling for
communications errors
Weight
214
CRT1-OD16S
16 outputs
NPN
0.5 A/output, 4 A/common
1.2 V max. (0.5 A
DC, between each
output terminal and
the G terminal)
0.1 mA max.
0.5 ms max.
1.5 ms max.
---
---
16 outputs/common
Photocoupler
LED (yellow)
DIN Track
Multi-power supply
100 mA/output
40 mA max. for 24-VDC power supply
voltage
60 mA max. for 14-VDC power supply
voltage
20 mA max. for 24-VDC power supply
voltage
Select either hold or clear from CX-Integrator.
110 g max.
Note
Please see "Appendix E: I/O Power Supply Current" regarding the I/O power
supply current supplied to the V and G terminals.
Specification
CRT1-OD16S-1
CRT1-OD16SH
PNP
NPN
1.2 V max. (0.5 A
1.2 V max. (0.5 A
DC, between each
DC, between each
output terminal and
output terminal and
the V terminal)
the G terminal)
Supported.
Operates at 3 mA/point max. (Does not
operate at over 3 mA.)
40 mA max. for 24-VDC power supply
voltage
65 mA max. for 14-VDC power supply
voltage
15 mA max. for 24-
VDC power supply
voltage
Section 5-4
CRT1-OD16SH-1
PNP
1.2 V max. (0.5 A
DC, between each
output terminal and
the V terminal)
60 mA max. for 24-
VDC power supply
voltage