Loading The Factory-Preset Default Configuration For The Conference System; Adding A Conference Console To An Already Existing Configuration; Removing A Conference Console From An Already Existing Configuration - Sennheiser SDC 8200 AO System Manual

Hide thumbs Also See for SDC 8200 AO:
Table of Contents

Advertisement

Configuring the SDC 8200 system
Initialise Units
3
Load Defaults
Initialise Units
1
Manual Init
Manual Init
2
Add Unit
Initialise Units
1
Manual Init
Manual Init
3
Delete Unit
86
As soon as the initialization of a conference console is accepted by the
central unit, the red signal light ring of the console goes off.
Press the ENTER key to save this configuration.
Loading the factory-preset default configuration for the conference sys-
tem
If necessary, you can load the factory-preset default configuration for the
conference system.
Note!
Loading the factory-preset default configuration will delete all setting
of your current configuration! Your conference system then has to be
re-configured to become operational!
To load the factory-preset default configuration for the conference sys-
tem:
From the central unit's operating menu, choose "
Initialise Units
"
" and "
Configuration
The text "
shown on the display.
Press the ENTER key to replace your current configuration by the fac-
tory-preset default configuration.

Adding a conference console to an already existing configuration

To add newly connected conference consoles to an already existing config-
uration:
From the central unit's operating menu, choose "
Initialise Units
"
" and "
The red signal light rings
conference consoles start flashing.
Add Unit
Choose "
".
Only the signal light rings of the conference consoles not yet initialized
remain flashing.
Press the microphone key
want to add to your configuration.
As soon as the initialization of a conference console is accepted by the
central unit, the signal light ring of the console goes off.

Removing a conference console from an already existing configuration

To remove a conference console from an already existing configuration:
From the central unit's operating menu, choose "
"
Initialise Units
" and "
The red signal light rings
conference consoles start flashing.
Delete Unit
Choose "
Mic. Number = 00
The text "
Load Defaults
" one after the other.
will
be
overwritten.
Manual Init
" one after the other.
and the "Microphone active" LEDs
of the conference consoles which you
Manual Init
" one after the other.
and the "Microphone active" LEDs
".
" is shown on the display.
Conference
",
Continue?
" is
Conference
",
on all
Conference
",
on all

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents