3 ADAPTATION TO DIFFERENT TYPES OF GAS

Before performing any cleaning or maintenance work, disconnect the appliance from the power
supply.
The cooker is set for LPG G30/G31 (3+) at a pressure of 28/37 mbar. In the case of functioning with
other types of gas the burner nozzles must be changed and the minimum flame adjusted on the gas
taps. To change the nozzles, proceed as described below.
3.1 Replacement of nozzles on the hob
This operation requires no primary air regulation.
1. Extract the racks and remove all the caps and flame-spreader crowns;
2. unscrew the burner nozzles with a 7 mm socket wrench;
3. replace the nozzles according to the type of gas to be used and the description in paragraph "3.2 /
3.3 Burner and nozzle characteristics table".
4. Replace the burners in the correct position.
3.2 Arrangement of burners on cooking hob
10
Instruction for the installer
BURNERS
1. Auxiliary
2. Semi-rapid
3. Rapid
4. Triple crown