Drive Unit Installation - Simrad AP16 Manual

Hide thumbs Also See for AP16:
Table of Contents

Advertisement

Simrad AP16 Autopilot
3.10

Drive unit installation

The relations between drive units, drive unit voltage, autopilot
computer, drive performance and interface to the steering gear
are shown in the tables below.
Refer to the connecting diagram for the different drive units on
page 62 onwards.
Installation instruction for the drive units are found in the
manual for the individual units.
The maximum drive current capability of the AC10, AC20 and
AC40 autopilot computers are different. Use the table below as
reference and observe the notes on next page.
MODEL
MOTOR
AUTOPILOT
VOLTS
COMPUTER
RPU80
12V
RPU160
12V
RPU300
12V
RPU300
24V
Steering gear interface: Hydraulic plumbing
Notes !
1. The AP16 system detects whether a reversible motor or a
2. The drive output of AC10 is sufficient for any type of 12 and
60
HYDRAULIC PUMPS
RAM CAPACITY
MIN
3
cm
(cu. in.)
AC10
80 (4,9)
AC20
160 (9,8)
AC40
290
(17,7)
AC20
290
(17,7)
solenoid is connected and outputs the correct drive signal
automatically.
24V solenoids normally found on a recreational boat.
FLOW RATE
MAX
AT 10 bar
3
3
cm
cm
/min
(cu. in.)
(cu. in/min)
250 (15,2)
800 (49)
550 (33,5)
1600 (98)
960 (58,5)
3000 (183)
960 (58,5)
3000 (183)
MAX
PWR.
PRESSURE
CONSUM-
bar
PTION
50
2,5-6 A
60
3-10 A
60
5-25 A
60
2,5-12 A
20221560E

Advertisement

Table of Contents
loading

Table of Contents