Drive Unit Installation - Simrad AP24 Installation Manual

Autopilots with autopilot computers
Hide thumbs Also See for AP24:
Table of Contents

Advertisement

2.8 Drive unit installation

The relations between drive units, drive unit voltage,
autopilot computer, drive performance and interface to
the steering gear are shown in the tables below.
Refer to the connecting diagram for the different drive
units on page 19 onwards.
Installation instruction for the drive units are found in the
manual for the individual units.
The maximum drive current capability of the AC12 and
AC42 autopilot computers are different. Use the table
below as reference and observe the notes on next page.
MODEL MOTOR
VOLTS
RPU80
12V
RPU160
12V
RPU300
12V
RPU300
24V
18 | Installation
LFI3000 Mk2
Interface
TB1
TB2
Figure 2-9 LF3000/LFI3000 Mk2 connections
RAM CAPACITY
AUTO-
MIN
3
PILOT
cm
COMPU-
(cu. in.)
TER
AC12
80 (4,9)
AC42
160 (9,8)
AC42
290 (17,7)
AC42
290 (17,7)
LF3000
Linear
Feedback
HYDRAULIC PUMPS
MAX
FLOW RATE
3
cm
AT 10 bar
3
(cu. in.)
cm
/min
(cu. in/min)
250 (15,2)
800 (49)
550 (33,5)
1600 (98)
960 (58,5)
3000 (183)
960 (58,5)
3000 (183)
Autopilot Computer
RUDDER
*
*
Non polarized
(color independent)
MAX
PWR.
PRESSURE
CONSUM-
bar
PTION
50
2,5-6 A
60
3-10 A
60
5-25 A
60
2,5-12 A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ap28Ac12Ac42

Table of Contents