REVERSE MECHANISM

2.5 REVERSE MECHANISM
[A]
The duplex unit starts when the entrance sensor [E] detects paper coming in.
1. Interchange unit gate [A]
Directs the paper to the duplex unit (up to A3 SEF)
2. Inverter roller [B]
Sends the paper to the inverter section [C]
3. Entrance sensor [E]
Detects the trailing edge of the paper
4. Inverter gate solenoid (behind [D])
Activates the inverter gate [D]
5. Inverter gate [D]
Switches the paper path
6. Inverter roller [F]
Changes its rotation direction (sends the paper to the exit path [G])
7. Transport roller [H]
Sends the paper to the main unit registration roller