CONNECT OUTPUT CABLES

WARNING
ELECTRIC SHOCK CAN KILL.
TURN THE POWER SWITCH ON THE
CV-300 OFF BEFORE MAKING CON-
NECTIONS TO THE OUTPUT TERMI-
NALS OR WIRE FEEDER RECEPTA-
CLE.
____________________________________
Note: Output cables must have Magnum Twist-Mate
plugs for connection to the CV-300. Order K852-95
Magnum Twist-Mate plugs (2 required) for connecting
2/0-3/0 (70-95 mm
2
) cables. Order K852-95 for con-
necting 2/0-3/0 (70-95 mm
Mate Cable Plug Installation Instructions section of this
manual.
1. Connect the positive output lead to the terminal
marked (+).
2. Connect the negative output lead to either the low
inductance terminal marked ( ) or the high induc-
tance terminal marked (
Note: Use the proper cable sizes for the work and
electrode cables as shown in the following table.
CABLE SIZES FOR COMBINED LENGTHS OF COP-
PER ELECTRODE AND WORK CABLE
Machine Size
Lengths up to
150 Ft.
300/100%
2/0 (70mm 2 )
(400/60%)

PARALLELING

The CV-300 is not designed to be paralleled with any
other power source.
INSTALLATION OF FIELD
INSTALLED ACCESSORIES
For installation of compatible field installed acces-
sories, refer to the instructions included with those
INSTALLATION
) cables. Refer to Twist-
2
).
Lengths from
150 to 200 Ft.
3/0 (95mm 2 )
IDEALARC CV-300
accessories.

INSTALLATION OF WIRE FEEDERS

Follow the instructions for the wire feeder that will be
used. See the Accessories section of this manual.
TWIST-MATE CABLE PLUG
WARNING
INSTALLATION INSTRUCTIONS
ELECTRIC SHOCK CAN KILL.
TURN THE POWER SWITCH OF THE
WELDING POWER "OFF" BEFORE
INSTALLING PLUGS ON CABLES OR
WHEN CONNECTING OR DISCON-
NECTING
POWER SOURCE.
____________________________________
1
Check that the connector boot is marked for the
appropriate cable size per table below; and strip
American
(Metric)
Boot Marking
Range Cable
Size
35-50
#2-#1 (35-50
50-70
1/0-2/0(50-70
70-95
2/0-3/0(70-95
the cable jacket to length specified:
2. If necessary, trim the cable end of the boot at
groove(s) to match the cable diameter. See Figure
A.6. Boot must fit tightly enough to seal around
outside diameter of cable.
NOTE: Some boots are designed to accommodate dif-
ferent cable diameters without trimming. These boots
do not have grooves at the cable end. Soap or other
non petroleum based lubricant will help to slide the
boot over the cable.
3. Slide the rubber boot onto cable end. See Figure
A.6.
4. Slide the copper tube into the brass plug. See
Figure A.6.
5. Insert cable into the copper tube. See Figure A.6.
A-7
PLUGS
TO
WELDING
Cable Skin
Length
2
)
1 inch (25.4
)
mm
mm
2
)
1 inch (25.4
)
mm
mm
2
)
1.5 inch (38.1
mm
mm
)