FIGURE A.5 - Reconnect Diagram for 230/460/575 voltage machines.
INSTALLATION
CONNECTION FOR
575 VOLTS 60HZ.
INPUT LINES
L3
L2
L1
GROUND
CONNECTION FOR
460 VOLTS 60HZ.
INPUT LINES
L3
L2
L1
GROUND
CONNECTION FOR
230 VOLTS 60HZ.
INPUT LINES
L3
L2
L1
GROUND
IDEALARC CV-300
1. Check nuts on terminal board for tight-
ness, then place the copper links in the
positions shown. Double up the links in
two of the positions to save them for
future use. Secure the links tightly with
the hex nuts provided. Secure the remain-
ing hex nuts in place for future use.
2. Connect L1, L2, & L3 as shown.
3. Connect terminal marked
minal per National Electrical Code.
1. Check nuts on terminal board for tight-
ness, then place the copper links in the
positions shown. Double up the links in
two of the positions to save them for
future use. Secure the links tightly with
the hex nuts provided. Secure the remain-
ing hex nuts in place for future use.
2. Connect L1, L2, & L3 as shown.
3. Connect terminal marked
minal per National Electrical Code.
1. Check nuts on terminal board for tight-
ness, then place the copper links in the
positions shown. Secure the links tightly
with the hex nuts provided.
2. Connect L1, L2, & L3 as shown.
3. Connect terminal marked
minal per National Electrical Code.