A-8
6. Tighten the set screw(s) to collapse the tube. The
screw(s) must apply firm pressure against welding
cable. The top of the set screw(s) will be nearly
flush or below the surface of the brass plug after
tightening.
7. Slide rubber boot over brass plug. The rubber
boot must be positioned to completely cover all
electrical surfaces after the plug is locked into the
receptacle.
WELDING CABLE
SEE
ABOVE
COPPER TUBE
FIGURE A.6 - Installing Twist-Mate Cable Plug.
INSTALLATION
BOOT
SET SCREW
TRIM
(70-95 SIZE MAY HAVE
2 SET SCREWS)
BRASS PLUG