EXTENDED (MONAURAL)
RECORDING
1 Load a recordable MD into the disc drive with the
label side up and in the direction of the arrow.
2 Press one of the function buttons and prepare
the source to be recorded.
To record from a tape, press the TAPE button and insert a
tape.
*To record from the radio, press the TUNER/BAND
button
and tune in to a station.
To record from equipment connected to the VIDEO/AUX
jacks, press the VIDEO/AUX button.
*To record from a CD, press the CD button and load a CD.
3 Press the MD MODE button twice.
"REC MODE?" is displayed for 10 seconds.
Pe Sg
4 Within 10 seconds, press the ENTER button and
turn the MULTI JOG dial so that "REC: MONO?"
is displayed.
5 Within 10 seconds, press the ENTER button.
"MONO" flashes on the display.
6 Press the MD MODE button.
"Mark MODE?" is displayed for 10 seconds.
i
7 Within 10 seconds, press the ENTER button and
turn the MULTI JOG dial to select an index mark
mode.
To register index marks automatically at the beginning of each
track, select "Mark: AUTO?".
To register index marks every 5 minutes, select "Mark: Time?".
To record without index marks, select "Mark: OFF?".
8 Within 10 seconds, press the ENTER button.
9 Press the MD REC button.
The unit enters the standby mode. Wait until the source name
selected at step 2 is displayed.
10 Press the II button to start recording.
When recording from connected equipment, start playback
of the connected equipment.
To stop recording
.
Press the lf button.
When recording stops, "TOC EDIT" is
displayed and the contents (TOC) of the recording are recorded
on the MD.
To add index marks during recording
Press the ENTER
button, and an index mark is registered
regardless of the index mark mode selected at step 7.
To record on a previously recorded MD
If there is an unrecorded section left on the MD, the new recording
automatically starts from where the previous recording finished.
If you want to start recording from the beginning of a previously
recorded MD, erase the previous recording completely.
(See
page 30.)
To cancel the extended recording mode
lf "MONO" flashes on the display, proceed as follows to cancel
the extended (monaural) recording mode.
71 Press the MD MODE buiton twice, and within 10
seconds, press the ENTER button.
"REC: STEREO?" is displayed.
2 Within 10 seconds, press the ENTER button.
"MONO" disappears on the display.
ENGLISH 26