Breath Control; Breath Curve - Yamaha MU100R Owner's Manual

Yamaha mu100r synthesizer: user guide
Hide thumbs Also See for MU100R:
Table of Contents

Advertisement

VL Voices and Harmony System Parameters (PLUGIN)

Breath Control

Settings:
BC, Exp
This determines the MIDI control change
number to be used for breath control of
the VL Voice, when breath controller data
(number 02) is received via MIDI. When
"BC" is selected, control number 02
(breath control) is used. When "Exp" is
selected, control number 11 (expression)
is used.

Breath Curve

Range:
-16 — +16
Determines the relationship between
breath controller data (number 02) re-
ceived via MIDI, and the actual amount
of breath variation applied. Negative set-
tings result in a large breath variation with
a relatively small amount of breath pres-
sure applied to the controller, while posi-
tive settings require a greater range of
input breath control values to produce the
same degree of breath variation.
Details
• This is also effective for breath controller
data transmitted from devices other than
those of the WX-series.
• The settings made here are effective only
when "BC/WX" is selected for the Breath
Mode.
170
Utility Mode

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents