Electrical Requirements; Environmental Requirements; Estimated Installation Time; Operating Supplies - Xerox DocuTech 6100 Planning Manual

Solutions planning guide
Hide thumbs Also See for DocuTech 6100:
Table of Contents

Advertisement

Xerox Document Stacker 5000 (DS5000)

Electrical Requirements

Environmental Requirements

Estimated Installation Time

Operating Supplies

Dimensions
Width x Depth x Height
39.4" x 28.7" x 47.2"
1000 mm x 730 mm x 1200 mm
Shipping Dimensions
47.2" x 31.5" x 55"
Width x Depth x Height
1200 mm x 800 mm x 1400 mm
Weight
551 lbs (250 kg) (includes 1 paper dolly)
Shipping Weight
661 lbs (300 kg)
Operator Clearance
Minimum 24" (610 mm) in front of the
device
Service Clearance
Minimum 30" (763 mm) on all sides of
the device
The recommended location of the electrical wall outlet is
mounted on a rear wall behind the DS5000.
Device
North America
DS5000
107 – 127 VAC (+/- 10%), 60
Power
Hz, 15A (single phase) GFI
Power Cord
Temperature
50 - 90° F (10 - 32°C)
Humidity
10 – 85%
Heat Emission
1700 btu / hr
Sound Emission
72 db
Altitude
No restrictions.
The Xerox CSE installs the DS5000 and the estimated
installation time is 1.5 hour.
There are no operating supplies for the DS5000.
1-3
Document Stacker 5000
Europe
220 – 240 VAC, (+/- 10%), 50
Hz, 13AmDPS/10A (line to
neutral) GFI Power Cord