Electrical Requirements - Xerox DocuTech 6100 Install Manual

Xerox docutech 6100: install guide
Hide thumbs Also See for DocuTech 6100:
Table of Contents

Advertisement

If passage or doorway
A is:
inches (mm)
29.0 (737)
30.0 (762)
31.0 (787)
32.0 (813)
34.0 (864)
36.0 (914)
38.0 (965)
40.0 (1016)
42.0 (1067)

Electrical requirements

DocuTech 61xx Installation Planning Guide
Table 4-3. Minimum passage widths
Minimum passage B width must be:
Finisher*
inches (mm)
55.5 (1410)
54.0 (1372)
52.0 (1321)
51.0 (1295)
47.0 (1194)
45.0 (1143)
43.0 (1092)
41.0 (1041)
39.0 (991)
*The Finisher module is smaller than the separated Processor
module. If there is sufficient passage width for the Processor
module, there also will be sufficient clearance for the Finisher
module.
This section describes the electrical requirements for installing
one or more DocuTech printers. When selecting a location for the
printer, the electrical requirements described in this section must
be met.
Select and prepare an installation site
Processor* inches (mm)
Not separated
(on casters)
83.0 (2108)
76.0 (1930)
73.0 (1854)
70.5 (1791)
66.5 (1690)
63.5 (1613)
61.5 (1562)
58.0 (1473)
55.0 (1397)
Separated
(on casters)
74.5 (1892)
64.5 (1638)
62.0 (1575)
59.5 (1511)
56.0 (1422)
53.0 (1346)
50.0 (1270)
48.0 (1219)
45.5 (1156)
4-9