Henny Penny FlexFusion FPG-221 Additional Installation, Operation And Maintenance Instructions page 35

Hide thumbs Also See for FlexFusion FPG-221:
Table of Contents

Advertisement

Check the resistance of the glow electrodes
ATTENTION! Wait at least 15 minutes after operation before performing the measurement.
Test criteria
• Both upper and lower burner
The electrical resistance of the glow electrode is between 1 to 6 Ω.
If no
Replace glow electrode.
Gas type
Natural gas A
LP Gas B/P gas E
Gas connection
• With which type of gas is the device operated?
natural gas E/H, G20, 8-inch WC (20 mbar)
Connection pressure OK (right side port on gas valve "a")?
• Is the connection pressure (dynamic pressure) OK at "High" power? (See "Checking the connection
pressure" in the installation instructions).
• If there are multiple units installed in one location, all other units in addition to the unit being checked
must run on maximum power.
Connection pressure (dynamic pressure):
If no,
Inform store manager.
Dynamic pressure (inch WC
(mbar))
8 (20)
12 (30)
liquid gas P, G31, 12-inch WC (30 mbar)
Gas connection
Maintenance instructions
Performing maintenance
Remarks / values
Dynamic pressure range (inch WC
(mbar))
6.8 - 10 (17 - 25)
10 - 14 (25 - 35)
a
Yes
No
Yes
No
35